Showing 1–36 of 90 results

Show sidebar

L&T Switchgear 100A RCCB 100 mA 2 Pole DP BG210010

5,242 inc. GST
Add to cart

L&T Switchgear 100A RCCB 100 mA 4 Pole FP BG410010

5,641 inc. GST
Add to cart

L&T Switchgear 100A RCCB 30 mA 2 Pole DP BG210003

5,174 inc. GST
Add to cart

L&T Switchgear 100A RCCB 30 mA 4 Pole FP BG410003

5,540 inc. GST
Add to cart

L&T Switchgear 100A RCCB 300 mA 2 Pole DP BG210030

5,242 inc. GST
Add to cart

L&T Switchgear 100A RCCB 300 mA 4 Pole FP BG410030

5,641 inc. GST
Add to cart

L&T Switchgear 25A RCCB 100 mA 2 Pole DP BG202510

2,201 inc. GST
Add to cart

L&T Switchgear 25A RCCB 100 mA 4 Pole FP BG402510

2,881 inc. GST
Add to cart

L&T Switchgear 25A RCCB 30 mA 2 Pole DP BG202503

2,100 inc. GST
Add to cart

L&T Switchgear 25A RCCB 30 mA 4 Pole FP BG402503

2,780 inc. GST
Add to cart

L&T Switchgear 25A RCCB 300 mA 2 Pole DP BG202530

2,201 inc. GST
Add to cart

L&T Switchgear 25A RCCB 300 mA 4 Pole FP BG402530

2,881 inc. GST
Add to cart

L&T Switchgear 40A RCCB 100 mA 2 Pole DP BG204010

2,516 inc. GST
Add to cart

L&T Switchgear 40A RCCB 100 mA 4 Pole FP BG404010

2,927 inc. GST
Add to cart

L&T Switchgear 40A RCCB 30 mA 2 Pole DP BG204003

2,377 inc. GST
Add to cart

L&T Switchgear 40A RCCB 30 mA 4 Pole FP BG404003

2,793 inc. GST
Add to cart

L&T Switchgear 40A RCCB 300 mA 2 Pole DP BG204030

2,516 inc. GST
Add to cart

L&T Switchgear 40A RCCB 300 mA 4 Pole FP BG404030

2,927 inc. GST
Add to cart

L&T Switchgear 63A RCCB 100 mA 2 Pole DP BG206310

3,037 inc. GST
Add to cart

L&T Switchgear 63A RCCB 100 mA 4 Pole FP BG406310

3,364 inc. GST
Add to cart

L&T Switchgear 63A RCCB 30 mA 2 Pole DP BG206303

2,961 inc. GST
Add to cart

L&T Switchgear 63A RCCB 30 mA 4 Pole FP BG406303

3,205 inc. GST
Add to cart

L&T Switchgear 63A RCCB 300 mA 2 Pole DP BG206330

3,037 inc. GST
Add to cart

L&T Switchgear 63A RCCB 300 mA 4 Pole FP BG406330

3,364 inc. GST
Add to cart

Legrand RCCB DX3 25A 100mA 2 Pole DP 240 V AC applications 4118 56

2,234 inc. GST
Add to cart

Legrand RCCB DX3 25A 100mA 4 Pole FP 415 V AC applications 4118 81

2,961 inc. GST
Add to cart

Legrand RCCB DX3 25A 300mA 2 Pole DP 240 V AC applications 4118 61

2,274 inc. GST
Add to cart

Legrand RCCB DX3 25A 300mA 4 Pole FP 415 V AC applications 4118 86

3,032 inc. GST
Add to cart

Legrand RCCB DX3 25A 30mA 2 Pole DP 240 V AC applications 4118 51

2,072 inc. GST
Add to cart

Legrand RCCB DX3 25A 30mA 4 Pole FP 415 V AC applications 4118 76

2,854 inc. GST
Add to cart

Legrand RCCB DX3 40A 100mA 2 Pole DP 240 V AC applications 4118 57

2,592 inc. GST
Add to cart

Legrand RCCB DX3 40A 100mA 4 Pole FP 415 V AC applications 4118 82

2,980 inc. GST
Add to cart

Legrand RCCB DX3 40A 300mA 2 Pole DP 240 V AC applications 4118 62

2,648 inc. GST
Add to cart

Legrand RCCB DX3 40A 300mA 4 Pole FP 415 V AC applications 4118 87

3,078 inc. GST
Add to cart

Legrand RCCB DX3 40A 30mA 2 Pole DP 240 V AC applications 4118 52

2,425 inc. GST
Add to cart

Legrand RCCB DX3 40A 30mA 4 Pole FP 415 V AC applications 4118 77

2,819 inc. GST
Add to cart

Why buy Residual Current Circuit Breaker?

Whenever we think about wiring and maintaining electrical safety in our homes, our thoughts end with a miniature circuit breaker (MCB). We do not realize that there are other things that we need to protect ourselves’ from, such as electrocutionwhich is often caused by earth leakage/residual current.

 

What is RCCB ?

 

RCCB is a safety device which protects human beings from electrocution as well as from fire caused by electrical shock.It monitors the current;whenever a fault occurs in earthing, it automatically disconnects the circuit, protecting everyone.

Earth leakage occurs, often due to poor wiring which causes parts of a wire to be exposed. This creates a separate path for the current to flow. If a person comes in contact with the exposed area, they get electrocuted.

 

 

A ‘fault’ occurs when there is difference between the current flowing in the live conductor and the neutral conductor.The RCCB checks this difference constantly. If the difference exceeds the rated sensitivity of the device, the RCCB trips, disconnecting the circuit.

 

Working Principle:-

The RCCB uses Kirchhoff’s Current Law as its working principle.

Kirchhoff’s Current Law states that for a parallel path the total current entering a circuit’s junction is exactly equal to the total current leaving the same junction.

For the safe functioning of the circuit, the amount of electric current flowing through the live conductor should be equal to the amount of current flowing inside the neutral conductor.

The RCCB senses this difference in the solenoid and within milliseconds the RCCB disconnects the supply of power to the circuit. This provides protection to the person.

Most RCCBs have a ‘rated sensitivity for leakage current’ of not more than 30 mA. A test button is provided with the device which on being pressed creates an imbalance in the neutral coil of the solenoid, the RCCB trips and supply is disconnected thereby checking RCCB’s reliability.

The above diagram shows an RCCB in an ‘open condition’, i.e., when the device has disconnected the circuit due to a ‘fault’.

Types of RCCB:-

RCCBs can be categorized under three groups-

  • Number of poles
  • Rated sensitivity
  • Type

 

Type of RCCB-

Type Symbol Characteristics Loads
AC Trips on AC only. Suitable for general use, such as immersion heaters.
A Same as that of type AC, in addition trips on pulsating DC. Suitable for domestic environments.
F Same as type A, in addition tripping is achieved for circuits with mixed frequency leakage circuits. They are able to provide protection against pulsating DC current. They are most suitable for frequency controlled equipments such as dishwashers, some air conditioners.
B Same for type F, in addition tripping is achieved for AC current up to 1kHz,

pulsating DC superimposed on a smooth DC.

3-phase and single-phase electronic equipment.

The above table shows the different type of RCCBs and the type of current they are sensitive to, i.e., they trip when they are able to sense this current in the circuit.

Usually, type AC RCCBs are most commonly used. The symbol shown in the table should be visible on the device which indicates the type of RCCB it is.

Number of poles-

The no. of poles in an RCCBindicates the number of conductors interrupted when a fault occurs. There are three kinds based on

2-pole- These are used in single-phase connections and disconnect both the conductors during a fault.

3-pole- These are used in three-phase AC connections but it only has three wire connections.

4-pole- Also used in three-phase AC connections but it also has an extra connection that connects to the neutral of the power supply.

Earth Leakage Circuit Breaker (ELCB)

This device has the same function as an RCCB but it is a voltage sensor device. They are suitable for three-phase circuits and high current loads.

The residual current level and tripping delay is often adjustable, thus allowing selectivity among different circuit breakers. Regardless, ELCB is an old device and the RCCB has better advantages.

Rated sensitivity-

RCCB sensitivity is expressed as IΔn. According to values defined by the IEC, RCCBs can be divided into:

  • High sensitivity: 5 – 10 – 30 mA (for direct-contact or life injury protection),
  • Medium sensitivity: 100 – 300 – 500 – 1000 mA (for fire protection),
  • Low sensitivity: 3 – 10 – 30 A (typically for protection of machine).

Advantages of RCCBs:-

  • It provides protection from earth faults as well as residual current.
  • Disconnects the circuit when rated sensitivity is exceeded within the circuit.
  • RCCBs have test buttons which on being pressed simulates a ‘false fault’ situation which causes the device to disconnect the circuit. This button comes in handy as it is used to see if the device is operational.
  • It also protects the circuit from voltage fluctuations (rise and fall in voltage levels).

Disadvantages of RCCBs:-

  • It cannot detect shot circuit and over-current faults. For this it must always be paired with an MCB.
  • It can only protect efficiently against electric shock if the current flows from phase to ground. It does not protect against electric shock if the current flows from phase-to-phase through a person or from phase-to-neutral.
  • Sometimes when there is a sudden change in electrical loads, it causes a slight amount of current to be directed to the earth (this occurs mostly in old appliances). RCCBs being very sensitive, trip causing the circuit to disconnect although there was no danger of electrocution.
 An MCB provides protection from both overload and short circuit. 

MCBs can be switched ON and OFF manually. MCBs and RCCBs are often used together in circuits to provide over-current, short circuit, electric shock and fire protection.

Major manufacturers:-