{"id":2030,"count":4,"description":"
\r\n

Main Switch<\/h1>\r\n\"main<\/a><\/blockquote>\r\nCurrent or power on entering the house passes through the main fuse and the meter. Thereafter comes the main switch and the main fuses of the house, then various circuits which are parallel to each other.\r\n

Switch<\/strong><\/h2>\r\nA switch is electrical equipment that helps discontinue, disconnect or continue, connect the flow of electrical energy in a circuit.<\/strong><\/em> An electrical switch would either allow or deny the flow of current due to its binary nature.\r\n

Main Switch Box<\/h2>\r\n

\"main<\/a><\/p>\r\nThe main switch also known as the master switch <\/span>makes or breaks the flow of current through all the circuits in your house, building, factory, etc. In a circuit breaker box, the first and biggest switch<\/span> is usually the main switch (about 60 to 100 amps)<\/strong> <\/em>followed by a row of smaller breakers (maybe 10 or 15 or 20 amps each) that go to each area of the house, like kitchen, or bathroom, or living room lights, or living room sockets hence called main circuit breaker.\r\n\r\nIf you\u2019re aware of an electrical panel then you might have realized the presence of various circuit breakers connected to different facilities and branches adjacent to each other.\r\n\r\nFor convenience, these circuit breakers or switches are either numbered or labeled. In either case, it\u2019s easy to identify the Main Switch or Main Circuit Breaker since it\u2019s situated either above\/below the row\/rows or switches also called circuit breakers, at the side or at the very center.\r\n\r\nLow voltage circuit breakers are used for residential purposes, medium voltage breakers for buildings like offices or factories (depending on the scale), and high voltage circuits for bigger facilities or areas may be a city.<\/strong><\/em>\r\n\r\n\"main<\/a>\r\n

Purpose<\/h3>\r\nThe purpose of the main circuit breaker is to provide security and safety<\/span> in a reliable manner against hazardous events that might occur, thanks to electric faults.\r\n\r\nThe branch circuit breakers have a lower capacity to bear fluctuations, hence there is a need for the main circuit breaker to handle the load.\r\n\r\nThe main switch trips off shunning power supply to the subsidiary circuits connected to varied branches averting spark, fire, and electric arc in case of surplus supply safeguarding the individual working on the circuit from shock and\/or death.\r\n

Operation<\/h3>\r\nThe circuit breakers or electrical switches are designed and developed specifically for preventing any hazardous occurrences. When closed, the circuit breakers allow the flow of current, and when this current exceeds the limit the breaker trips preventing overflow of current.\r\n\r\nThe low-voltage circuit breakers in residential electrical panels bring 240V of power through two wires each with the capacity of 120V. They use the stored energy in the spring to throw the switch and separate contact with the circuit. This enables you to manually cut off and reset the power delivery with the flip of a switch.\r\n

Working<\/h3>\r\n\"main<\/a>\r\n\r\n\u2022 The branch circuit breakers are subsidiary to the main circuit breaker.\r\n\u2022 The power flows through the main circuit breaker to the branch circuit breakers, which successively supply this energy to the concerned branches or areas for instance in the kitchen, garage, and so on.\r\n\u2022 The main circuit breaker is built conforming to the safety standards with a specified amount of amperage.\r\n\u2022 When the current passing through this main circuit breaker exceeds its specified limit the circuit is automatically severed when the breaker trips, restricting the flow of current.\r\n\u2022 This simultaneously restricts the flow of current to the branch circuit breakers killing the flow of electricity for the entire facility.\r\n\u2022 Usually this problem never occurs since the branch circuit breakers shut off power to individual circuits in case of overload.\r\n\r\nThe reason that these circuit breakers could trip is power surges, problems in the system, more power demand leading to overload, etc.<\/strong><\/em>\r\n

Manual or Voluntary Shut-off<\/h3>\r\nIf the power supply needs to be cut off for reasons such as repair or maintenance the following steps should be taken:\r\n\r\n\u2022 Firstly<\/strong><\/em> take precautions while working with electrical equipment<\/strong> <\/em>that is recommended.\r\n\u2022 The main breaker<\/strong><\/em> which is the source of electricity in the facility should not be touched immediately<\/strong> <\/em>in order to cut off the power supply.\r\n\u2022 The branch circuit breakers should be carefully and individually shut off<\/em> <\/strong>in order to prevent any mishap.\r\n\u2022 After affirming that the individual branch circuit breakers have been carefully shut off the main circuit breaker should be turned off.\r\n\u2022 When it comes to restoring the supply of electricity the same process should be followed in reverse.\r\n\u2022 This implies that after flipping ON the main circuit breaker, individual circuit breakers should be flipped ON one at a time to prevent the sudden flow of current.\r\n

Precaution<\/h3>\r\n\"Switch<\/a>\r\n\r\nAlthough the main circuit breaker trips once in a blue moon, if this happens often it will depreciate the capacity of the main breaker, lowering its amperage capacity. This can be rectified by simple mechanical tools and skills.\r\n

Best Circuit Breakers Brands:<\/h2>\r\n1. Schneider Electric<\/a><\/strong><\/span>\r\n\r\n\"\"<\/a>\r\n\r\n2. Havells<\/a><\/span><\/strong>\r\n\r\n\"\"<\/a><\/span><\/strong>\r\n\r\n3. Siemens<\/a><\/span><\/strong>\r\n\r\n\"\"<\/a>\r\n\r\n4. ABB<\/strong>\r\n\r\n\"\"<\/a>\r\n\r\n5. L & T<\/strong>\r\n\r\n\"\"<\/a>\r\n\r\n6. Legrand<\/a><\/strong><\/span>\r\n\r\n\"\"<\/a><\/strong><\/span>\r\n\r\n7.\u00a0Anchor<\/a><\/strong><\/span>\r\n\r\n\"\"<\/a>\r\n

Important Characteristics to be Studied Before Buying<\/h3>\r\n\u2022 Voltage Rating<\/span><\/strong>\r\n\u2022 Amperage Capacity<\/span><\/strong>\r\n\u2022 Breaking Capacity<\/span><\/strong>\r\n\u2022 Operating Conditions<\/span><\/strong>\r\n

Conclusion<\/h3>\r\nAlthough the main breaker seldom trips you can never be fully sure of the surges in electricity. Since you\u2019ve invested your hard-earned money on appliances it\u2019s your responsibility to protect them from harm that are avoidable.\r\n\r\n\"main<\/a>\r\nAlso these devices are necessary not only for the safety of products but also life.\r\n\r\nThe outputs of the main switch are connected to the PDU. From here, one of the phases will power the power supplies and goes into the terminal block as well.<\/span>\r\n\r\nPower supply input maybe 100 to 240 volts AC. These power supplies convert the AC signal to a DC voltage output, 24 volts in one case, and 12 volts in the other. This DC power supply can then be used for the devices of the control panel, or for the devices on the ground too!<\/span>\r\n\r\nThe 3-phase power supply passing through the terminal block can be used to power devices that operate with a 3-phase power supply.<\/span>\r\n\r\nWhen we put the main switch to the \u20180\u2019 position, the incoming 3 phase supply power will be disconnected, and that shuts down the whole control panel, including all of the devices that work with DC power, and also the devices that work with 3 phase power.<\/span>","link":"https:\/\/www.ampkart.com\/starters-and-switches\/main-switch-and-hrc-fuses\/main-switches\/","name":"Main Switches","slug":"main-switches","taxonomy":"product_cat","parent":2029,"meta":[],"cat_url":"https:\/\/www.ampkart.com\/starters-and-switches\/main-switch-and-hrc-fuses\/main-switches\/","_links":{"self":[{"href":"https:\/\/www.ampkart.com\/wp-json\/wp\/v2\/product_cat\/2030"}],"collection":[{"href":"https:\/\/www.ampkart.com\/wp-json\/wp\/v2\/product_cat"}],"about":[{"href":"https:\/\/www.ampkart.com\/wp-json\/wp\/v2\/taxonomies\/product_cat"}],"up":[{"embeddable":true,"href":"https:\/\/www.ampkart.com\/wp-json\/wp\/v2\/product_cat\/2029"}],"wp:post_type":[{"href":"https:\/\/www.ampkart.com\/wp-json\/wp\/v2\/product?product_cat=2030"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}